Amalia Technologies has entered a partnership with S-PACT, developer of the PEAXACT software suite for quantitative process spectroscopy. The partnership pairs S-PACT's chemometric tools with Amalia's Process Analytical Technology (PAT) and Good Practice (GxP) compliance services. For life sciences manufacturers, it offers one route from a spectral model in the lab to a validated, governed, and monitored process in production.
Start with the control strategy, not the instrument
PAT earns its place when it answers a question the control strategy needs answered. Which quality attribute is at risk, at which unit operation, and what decision will the measurement inform? A probe installed without that answer produces data. It rarely produces control.
We begin every engagement there. We define the purpose of the measurement and the process understanding behind it, and whether its role is monitoring, in-process control or, eventually, real-time release testing. That choice sets everything downstream, including the level of validation the model will need and who will own it. It also forces an honest look at sampling. A model can only be as representative as the material presented to the probe.
What PEAXACT brings
PEAXACT covers the full spectroscopic workflow. Its Desktop App handles model development, including mechanistic models like peak integration and Spectral Hard Modeling, a physics-informed approach that uses process knowledge to reduce the calibration effort that purely statistical models usually demand. Predictors run those models in real time inside a PAT environment – directly on a spectrometer device, as a stand-alone solution, or embedded in process orchestration software. For teams that prefer a ready-made solution, S-PACT builds custom Analyzer Apps and maintains them throughout the lifecycle as the process changes.
PEAXACT reads all peak-shaped data – amongst the most common are Raman, mid-infrared (MIR), near-infrared (NIR), ultraviolet-visible (UV-VIS) and nuclear magnetic resonance (NMR), but also XRF, XRD, Fluorescence data from any instrument, regardless of the manufacturer. That last point matters: few sites run a single instrument brand of spectrometer, and software locked to one vendor would leave the rest of their instruments unsupported.
Why validation sits at the centre
A chemometric model that performs well on a laboratory dataset is not yet a production tool. Once its output informs a quality decision, the model and the software running it become part of a computerised system, and regulators expect that system to be under control.
This is where many PAT projects stall. The model works. The evidence that it works, reliably and traceably, does not exist yet.
Amalia's compliance services close that gap. We apply risk-based Computerised System Validation (CSV) and Computer Software Assurance (CSA) to PAT software, so the validation effort matches the actual risk of each function rather than defaulting to exhaustive testing. We address data integrity for spectral data and predicted values, and we set up change control for the point that every PAT model eventually reaches: the process drifts, a raw material supplier changes, and the model needs updating. No modelling approach removes the need for validation. It only changes where the evidence comes from, and the validation approach has to reflect that.
Why governance decides whether it reaches production
An inline spectroscopy deployment is rarely a single task. It touches the analytical method, the automation and control system, the quality organisation, the data platform, and often an instrument supplier, each on its own timeline. Technical merit alone does not carry a project through that. Without someone holding those threads together, the pieces arrive in the wrong order and the deployment stretches.
Amalia runs the deployment as a managed programme. From feasibility through to routine production, we can coordinate the analytical, automation, and quality workstreams, and manage the cutover from project to a monitored process, including the handover to the people who will run and maintain the model day to day. Ownership of the model lifecycle is agreed before go-live: who reviews performance, what triggers an update, and how that update passes through change control. A model maintained this way does not depend on the one person who built it.
Looking ahead
Amalia and S-PACT will work together on feasibility studies and implementations where PEAXACT models are intended for use in GxP manufacturing.
If you are assessing whether inline spectroscopy can support your control strategy, or need to bring an existing chemometric model under validated, governed control, Amalia's workstreams can help define a practical route from model to production.